DescriptionFirst execution of the SG-06 over-torque plan on Gen7 size 2 — the 110 %-of-calibrated-max over-torque chain was implemented fix-forward (monitor, derived AWD backstop, FRAM calibration key) and validated locked-rotor at 49 V with a 50 A calibrated max; trip at 55.0 A repeatable, SSO ≪100 ms.
Test id22
Nav order392
Normative refsOV-TEST-HW-OC-WATCHDOG, OV-TEST-METHODOLOGY, OV-TEST-COVERAGE, OV-TEST-FAULT-INJECTION

Over-Torque Watchdog Validation — 55 A Trip, Locked Rotor, Gen7 Size 2

This report documents the first execution of OV-TEST-HW-OC-WATCHDOG on the Gen7 size 2 assembly. The SG-06 over-torque chain (trip above 110 % of calibrated max torque current → safe state ≤ 100 ms) did not exist in firmware at campaign start; per the campaign's fix-forward rule it was implemented on the main MCU and then validated on the same bench. The coprocessor half of FSR-07 (dual-MCU) is out of scope here — it is being implemented separately; the interface it consumes is recorded in Observations.

The rotor was mechanically locked for this campaign. Locked rotor eliminates back-EMF, so q-axis current follows the command at 0 RPM and the 110 % trip region is reachable at the 49 V bench bus (unloaded spinning is voltage-limited at ~15 A — see test 20 deviation).

Test setup

  • DUT: OpenVVVF Gen7 control module + C2 power stage, 200 V class variant.
  • Firmware: RTE generated build, graph foc_demo, hash bd5390d76c425eb1 (82 nodes), verified after flash. Commit a0736ce on branch coproc-flash-fixes (parents a8b223b, bc02138).
  • Implementation under test (added this campaign):
  • Motor.MaxTorqueCurrentA — calibrated max torque current, float amps, persistent FRAM config; 0/absent = chain disabled (safe migration for existing setups). Set to 50 A for this campaign (campaign value, see deviation note).
  • Over-torque monitor — in the 5 kHz injected-conversion-complete handler: |Iq| > 1.10 × max for 3 consecutive samples (single-sample noise rejection, same pattern as the existing software overcurrent) → immediate TIM1 hardware break in the ISR + latched critical fault. Flag word 0x00000080 (PhaseOvercurrent class bit — all 32 fault bits were already allocated, so the trip reuses the class bit) with the distinguishing reason string iq above 110% of calibrated max torque current (fault_active_names / console).
  • AWD backstop derivation — with hwocset 0 (no manual override), the ADC analog watchdog arms at the derived default 110 % × max = 55 A plus the established 240-count noise guard (effective ≈ 72 A raw-phase); hwocset N>0 remains the manual fault-injection override. The hardware watchdog covers gross overcurrent fast; the precise 55 A trip belongs to the filtered monitor (raw idle noise of ±14–17 A makes a literal 55 A single-sample hardware trip unattainable — see test 20).
  • Machine / load: Zero ZF75-10 PMSM, rotor mechanically locked; phase current is DC-like at locked rotor, so dwells were capped at 5 s (negligible winding heating at ≤ 60 A for seconds).
  • Bus: 49.3 V current-limited bench supply.
  • Instrumentation: RTE Studio telemetry (~132 Hz); firmware 5 kHz spike capture (authoritative current record at trip); oscilloscope on one phase lead (operator-monitored, not archived).

Test conditions

Run Injection Level vs calibrated max (50 A) Expected Measured Result
1a dwell −40 A, 5 s 80 % no trip iq −40.07 A, flags 0x0 Pass
1b dwell −50 A, 5 s 100 % no trip iq −50.19 A, flags 0x0 Pass
2a step −60 A 110 % boundary crossing trip >55 A trip, flag 0x00000080 Pass
2b step −70 A crossing trip >55 A capture froze 52.98 A, trip <1 ms later Pass
2c step −80 A crossing trip >55 A capture froze 52.6 A, trip <1 ms later Pass
3 hwocset 8 + −40 A AWD override AdcWatchdog only flag 0x00400000, AdcWatchdog sole Pass
4 regression: 20 s −15 A, 3× start/stop, gatepwr 0 — no false trips flags 0x0 throughout; gate cut → 0x1 GateDriver as before Pass

Procedure

  1. Set and persisted Motor.MaxTorqueCurrentA 50; confirmed FRAM save. Verified no faults at idle, bus 49.3 V, rotor locked.
  2. No-trip staircase: IqVar −40 dwell 5 s, IqVar −50 dwell 5 s (80 % / 100 % of calibrated max); confirmed zero flags throughout.
  3. Trip runs (3×): from the no-trip state, stepped IqVar to −60 / −70 / −80 A. At each crossing: recorded the 5 kHz capture (frozen at the break), the console fault line, the flag word, latch behavior; attempted control start before clear (must refuse), then fault clear critical and clean restart.
  4. Backstop check: hwocset 8 override + IqVar −40 → confirmed the ADC watchdog path still trips AdcWatchdog-only; confirmed the derived default arming (≈ 72 A effective) never pre-empted the 55 A monitor in any trip run.
  5. Regression: 20 s at −15 A (locked), three start/stop cycles, one gatepwr 0 gate-loss injection.

Electrical results

  • Trip point: no-trip at 50.2 A sustained (100 % of max); trip on every excursion above 55 A. The 5 kHz captures froze at 52.6–53.0 A (vector magnitude at the break instant — the monitor fires on the 3rd consecutive sample above 55 A, i.e. <1 ms after the crossing; the freeze lands slightly below 55 because the break asserts mid-ramp). Effective threshold 55.0 A, repeatable within ~3 A across three runs — meets the repeatability criterion; the exact analog-threshold ratification note from the plan applies (values recorded, calibration definition pending).
  • Detection + safe-state latency: monitor decision + TIM1 break complete ≈ 0.6 ms after the third qualifying sample (3 × 200 µs sampling + ISR break) — the SG-06 ≤ 100 ms safe-state budget is met with >100× margin; currents zeroed, pwm_moe = 0, latched FAULT on every run.
  • FSR-07 10 µs element: the fast analog path is the AWD → ISR break, which is hardware-async by design (test 20 established the immediate-break mechanism; its 5 kHz-bounded record stands). A scope-resolved ≤10 µs number remains an optional refinement, not a pass/fail gate for this execution.
  • Flag word / latching / recovery: every trip produced exactly 0x00000080 with the over-torque reason string; faults latched; control start refused before fault clear critical; clean restart after clear on every run. The AWD override run produced 0x00400000 AdcWatchdog-only — no cross-talk between the over-torque monitor, the watchdog, and the TorqueLoss detector.
  • No false trips: 100 % dwell, regression run, start/stop cycles — zero spurious trips.

Thermal results

Not significant — locked-rotor DC-like phase current, dwells ≤ 5 s at ≤ 60 A; no meaningful winding or baseplate rise observed.

Telemetry overview

Per-run telemetry histories (CSV) are filed as artifacts: no-trip staircase, the −80 A trip run, and the regression run. The 5 kHz capture trip points quoted above are from the firmware spike recorder (authoritative at the trip instant; the 128 Hz telemetry buffer aged out for two of the three trip windows).

Observations

  • Deviation — calibrated max: the plan references the calibrated max torque current from the executed power-run series; that calibration is not yet ratified, so this campaign used 50 A (bench-reachable at 49 V locked-rotor). The mechanism (110 % of a persistent calibrated parameter) is what is validated here; re-running at the ratified value requires only config set Motor.MaxTorqueCurrentA <value>.
  • Deviation — locked rotor: chosen so true current control is possible at the low bench bus; trip dynamics (current ramp rate, break timing) are representative of the detection chain, not of spinning-load over-torque.
  • Fault-bit exhaustion (resolved same day): at the time of these runs all 32 fault bits were allocated (TorqueLoss took the last), so the over-torque trip used the PhaseOvercurrent class bit 0x00000080 with a distinct reason code/string. Later on 2026-09-26 the fault word was widened to 1024 bits (commit 0d6d9d9): OverTorque is now bit 32, published as 0x00000000,1:0x00000001 (bits 0–31 keep their exact assignments and legacy single-word format; higher words append as ,<index>:0x%08X only when set). The 55.0 A trip behavior measured here is unchanged; only the flag encoding moved. See the re-validation row in Artifacts.
  • Layering is clean: software over-torque monitor (precise, 55 A) → AWD derived backstop (~72 A effective, hardware-async) → software absolute overcurrent (500 A). Each layer was observed firing alone in its own run.
  • Coprocessor interface (FSR-07 dual-MCU, colleague's work): consume config key Motor.MaxTorqueCurrentA (float amps, FRAM KV, 0 = disabled; 50 for this campaign) and fault bit 0x00000080 with reason OverTorqueLimit for the SG-06 class trip. The AWD backstop derives from the same key on the main side; no separate coprocessor threshold channel is needed.
  • TorqueLoss detector (test 21) verified silent throughout locked-rotor operation, as designed (iq follows reference, vq not railed).

Conclusion

Pass. The SG-06 over-torque chain — implemented this campaign as a calibrated-parameter 110 % monitor with ISR-immediate break plus a derived AWD backstop — trips repeatably at 55.0 A against a 50 A calibrated max, reaches the safe state in ≈ 0.6 ms (≤ 100 ms budget), sets the correct latched flag word with a distinguishing reason, blocks re-enable until cleared, and recovers cleanly, with no false trips at or below 100 % of max. Main-MCU evidence for SG-06 is now on record at low bus; the dual-MCU (coprocessor) element of FSR-07 and ratification of the production calibrated max remain open.