Induction Motor Calibration Validation
This section validates the inverter's motor self-commissioning routines on a TECO MAX-IE3 7.5 kW induction motor. This is a separate machine class from the PMSM used in the main motor calibration report, so it gets its own test report.
- Induction Motor Testbed - hardware setup and reference information
- Induction Motor Resistance Calibration Validation - completed, compared against LCR reference
- Inductance Calibration Validation - completed at 40/80/120 V bus, compared against LCR reference (~18.3 mH estimated vs 17.86 mH reference)