OV-TEST-HW-DESAT-SHORT · v0.1 · 2026-09-24Download PDF
| Doctype | Test Plan |
|---|---|
| Doc id | OV-TEST-HW-DESAT-SHORT |
| Product line | openvvvf |
| Applies to | openvvvf-control-module, chassis-size-2 |
| Version | 0.1 |
| Date | 2026-09-24 |
| Description | Exercises the SG-12/SG-14 short-circuit protection by energizing the inverter into a pre-faulted phase at ≤140 V and verifying DESAT detection <2 µs, soft turn-off, FLT routing to both MCUs, and safe state. |
| Nav order | 388 |
| Placeholder | True |
| Normative refs | OV-TEST-METHODOLOGY, OV-TEST-COVERAGE, OV-TEST-FAULT-INJECTION |
Short-Circuit / DESAT Protection (Energize-Into-Fault)
Methodology archetype D — protection validation per OV-TEST-METHODOLOGY §4: the protection chain is exercised deliberately, and a non-trip is a fail.
Purpose & safety traceability
This plan validates the short-circuit protection chain allocated to:
- SG-12 (ASIL C, hazard H-12): prevent shoot-through; risk reduction → PWM disable <10 µs via hardware.
- FSR-13: DESAT detection on all six IGBTs — threshold VTH 6.5 V, local disable <2 µs, soft turn-off, active Miller clamp, gate-driver UVLO at 12.2 / 11.3 V.
- SG-14 (ASIL C): a gate-driver fault (DESAT/UVLO/TSD) drives the system to a safe state via OR'd FLT routed to both MCUs.
- LIMIT-10: no mid-operation short injection is possible on this hardware; the test is energize-into-fault only, at ≤140 V.
Quantified budgets under test: DESAT detection <2 µs, hardware PWM disable <10 µs, and FLT asserted to both MCUs with safe-state output (SSO) within ≤200 ms.
This complements the existing protection-validation evidence — the overtemperature chain in OV-TEST-HW-THERMAL-OTP-200A-GEN7-SIZE2 — by covering the short-circuit path, which no executed run has exercised yet (see coverage status in OV-TEST-COVERAGE). It is filed as a hardware test (physical DUT) that consumes the energize-into-fault constraints of OV-TEST-FAULT-INJECTION. No firmware change is expected for this test; if DESAT/FLT telemetry capture requires a firmware build not yet available, execution is blocked on that build and the report must record the firmware graph + hash actually used.
Scope
- DUT variant: [FILL: chassis size 2 assembly, bus class (200 V vs 450 V), thermal interface state] — selected per the variant matrix §6 of OV-TEST-METHODOLOGY.
- Protection scope: DESAT local disable + soft turn-off per IGBT, OR'd FLT routing to main MCU and coprocessor, safe-state output, gate-driver UVLO behavior (recorded if practical).
- Out of scope: mid-operation short injection (LIMIT-10), shoot-through injection between phase legs, bus voltages above 140 V, and TSD (thermal shutdown) triggering — covered by thermal campaigns.
Bench setup & preconditions
Per methodology §1, adapted for a fault-injection bench:
- DUT: Gen7 control module + C2 power stage; thermal interface state recorded; firmware graph + hash logged.
- Pre-faulted fixture: [FILL: fixture design — shorted phase leg via bolted/low-inductance short, switched by a contactor so the fault is applied before energize].
- DC supply: current-limited bench supply, [FILL: supply model and current limit], setpoint ≤140 V for this campaign.
- Machine: [FILL: machine and its thermal limit, if the fault leg is machine-coupled rather than bench-shorted].
- Instrumentation: high-sample-rate oscilloscope on DESAT pin, gate-emitter, and FLT lines (differential, rated for the bus class); RTE Studio telemetry; TI250-class imager for post-event inspection.
- Safety: a hard short on an energized inverter stores destructive energy. All personnel safety interlocks (emergency stop, discharge path, exclusion zone, PPE) must be documented before the first shot; the supply current limit and ≤140 V cap are mandatory preconditions; verify DC-link discharge to a safe voltage before touching the fixture between shots.
- DC-link capacitance (transfer-critical): the DC-link capacitors are the fault energy source — E ≈ ½·C·V². Record total capacitance and bus voltage for every shot. Results do not transfer to another voltage class or a significantly different capacitance without re-validation or an explicit energy-bound argument (methodology, "Component stress by archetype").
Procedure
- Fixture checkout: verify the shorted leg's impedance and the contactor operation with the DUT unpowered; record fixture identifiers and the current-limit setting. Capture: fixture photos, short impedance measurement.
- Baseline: power the DUT with the fault contactor open; confirm clean boot, no fault flags, and normal gate waveforms. Capture: boot log, baseline gate/DESAT scope traces.
- Pre-charge and arm: close the fault contactor to apply the pre-fault; set the supply to ≤140 V with the current limit active; confirm the DUT is commanded to a defined energize state (per [FILL: energize command/state]). Capture: supply settings screenshot.
- Energize into fault: apply bus power; the DESAT chain must trip locally. Capture at high sample rate: DESAT pin voltage vs the 6.5 V threshold, gate-emitter during soft turn-off, phase current decay, and FLT line on both MCU paths.
- Record latency: from the scope/telemetry timestamps, extract fault onset → DESAT assertion (<2 µs budget) and fault onset → hardware PWM disable (<10 µs budget). Capture: measurement screenshots with cursors.
- Safe-state verification: confirm the OR'd FLT is received by the main MCU and the coprocessor and that the safe-state output is asserted within ≤200 ms; record the FAULT flag words in telemetry. Capture: telemetry excerpt + flag dump.
- Post-event inspection: with the bus discharged, inspect the faulted IGBT leg (imager pass, visual check) and power the DUT again at low bus to confirm it still boots and runs — the DUT must survive for post-test insulation/functional checks.
- UVLO check (if practical): ramp the gate-driver supply down and up and record the UVLO trip thresholds against 12.2 / 11.3 V. Capture: ramp plot with trip points.
- Repeat steps 3–8 for [FILL: number of shots / repetitions per variant], cooling to ambient between shots.
Measurements & acceptance criteria
| # | Criterion | Pass condition |
|---|---|---|
| 1 | DESAT detection latency | <2 µs from fault onset to local disable, per IGBT faulted |
| 2 | Hardware PWM disable | <10 µs (SG-12 budget) |
| 3 | Turn-off behavior | Soft turn-off observed; no destructive overshoot on VCE; active Miller clamp active; DUT undamaged |
| 4 | FLT routing | OR'd FLT asserted at both MCUs; SSO within ≤200 ms of fault |
| 5 | Fault flags | Correct FAULT flag word recorded in telemetry for the faulted leg |
| 6 | DUT health | DUT survives; post-test insulation/functional check passes |
| 7 | UVLO thresholds | 12.2 / 11.3 V verified, or deviation noted as an observation with measured values recorded for ratification |
Where a value is pending definition at the safety-requirement level (e.g. final UVLO ratification thresholds), the test records the measured values and flags them for ratification rather than asserting compliance.
Evidence package
Per methodology §5, the resulting Test Report must include:
- Report sections: Test setup, Test conditions (table), Procedure, Electrical results, Observations, Conclusion, Artifacts.
- Telemetry overview plot in the standard 5-panel layout (Iq; DC-link power; machine-terminal P and Q; baseplate NTCs with ambient reference; bus voltage) — for this protection test annotated with the fault-onset marker.
- Full-rate session log + 1 Hz decimated log, decimated log linked in the Telemetry Viewer.
- High-sample-rate scope captures: DESAT vs 6.5 V threshold, gate soft turn-off, FLT both paths, current decay.
- Photos: fixture, contactor/short assembly, post-event DUT inspection, imager passes with crosshair/max readings.
- Naming and doc_id per the Testing naming convention in Docs/Agents.md.
Execution record
To be filed as a sibling Test Report under Docs/Safety-and-Compliance/Testing/Hardware/ referencing this plan by doc_id OV-TEST-HW-DESAT-SHORT; test ID assigned at execution.